Where to Buy Pump–probe Measurement Equipment
Pump–probe measurements can be used for studying ultrafast temporal evolution e.g. in semiconductor devices. They rely on one or two sources of ultrashort laser pulses, the timing of which can be varied.
E | See also our encyclopedia article on pump–probe measurements! Related articles: optical sampling, saturable absorbers, semiconductor saturable absorber mirrors, laser spectroscopy |
Related products: time-resolved spectroscopy equipment
Related product categories: detectors and measurements, applications
8 suppliers for pump–probe measurement equipment are listed in the RP Photonics Buyer's Guide. Both manufacturers and distributors can be registered.
Suppliers with Ad Package | |
---|---|
Company | Product Description |
APE Angewandte Physik und Elektronik GmbH Plauener Straße 163–165 / Haus N 13053 Berlin Germany | The APE ScanDelay is a variable optical delay line, allowing the introduction of a well-defined time delay into an optical path – for example, for pump–probe measurements. The delay is periodically controlled by a fast scanning shaker at a frequency of up to 20 Hz. The heart of APE’s optical delay line series is a special linear translation stage that is supplied together with appropriate control and drive electronics. The linear drive has been designed especially for optical applications. It combines low moving mass with compactness, reaching a high speed, as well as high precision and resolution. The delay drive moves frictionless, has a large and precise travel range, and allows for very small displacements without any stick-slip-effects. The control electronic contains the motion driver and a quartz stabilized signal synthesizer. It can be synchronized with an external clock for a precise, phase-locked scanner movement. |
All wavelengths. Lochhamer Schlag 19 82166 Gräfelfing Germany Quality: ISO 9001:2015 www.toptica.com Social: Facebook, LinkedIn, YouTube E-mail: Tel.: +49 89 85 83 70 Fax: +49 89 85 83 72 00 | TOPTICA contributes to the field of pump–probe measurements with newest fiber technology which is outstanding in performance and versatility. A single laser system can be equipped with various outputs that are intrinsically optically synchronized down to the attosecond level. All of these can be configured individually to satisfy the experimental needs: Pulse durations as short as 15 fs or broad tuning ranges of 490 nm to 700 nm, 850 nm to 1000 nm or 980 nm to 2200 nm are available. Within the third generation of TOPTICA’s ultrafast fiber lasers a novel, versatile toolbox is available to realize even more advanced pump–probe spectroscopy schemes. The FemtoFiber dichro bioMP outputs two different wavelength simultaneously (1050/780 nm at 150 fs), while the system can control the relative time delay of both colors and the GDD as well. |
Emery Court Stockport, Cheshire SK4 3GL United Kingdom www.laserquantum.com Social: Facebook, LinkedIn, Twitter, YouTube E-mail: Tel.: +44 161 975 5300 Fax: +44 161 975 5309 | Laser Quantum provides a range of continuous wave and ultrafast laser solutions, including the ASOPS Engine, a system comprising of two taccor femtosecond lasers and a TL-1000 ASOPS off-set-lock for frequency stabilization, enabling two-colour pump–probe experiments. |
Your company's products are not listed here? Get our ad package to enjoy that and many other benefits! |
All Suppliers | |
---|---|
APE Angewandte Physik und Elektronik GmbH Plauener Straße 163–165 / Haus N 13053 Berlin Germany | The APE ScanDelay is a variable optical delay line, allowing the introduction of a well-defined time delay into an optical path – for example, for pump–probe measurements. The delay is periodically controlled by a fast scanning shaker at a frequency of up to 20 Hz. The heart of APE’s optical delay line series is a special linear translation stage that is supplied together with appropriate control and drive electronics. The linear drive has been designed especially for optical applications. It combines low moving mass with compactness, reaching a high speed, as well as high precision and resolution. The delay drive moves frictionless, has a large and precise travel range, and allows for very small displacements without any stick-slip-effects. The control electronic contains the motion driver and a quartz stabilized signal synthesizer. It can be synchronized with an external clock for a precise, phase-locked scanner movement. |
Emery Court Stockport, Cheshire SK4 3GL United Kingdom www.laserquantum.com Social: Facebook, LinkedIn, Twitter, YouTube E-mail: Tel.: +44 161 975 5300 Fax: +44 161 975 5309 | Laser Quantum provides a range of continuous wave and ultrafast laser solutions, including the ASOPS Engine, a system comprising of two taccor femtosecond lasers and a TL-1000 ASOPS off-set-lock for frequency stabilization, enabling two-colour pump–probe experiments. |
Albert-Einstein-Str. 18 86899 Landsberg am Lech Germany | |
Via G. Durando 39 Milan, 20158 Italy | www.nireos.com E-mail: |
2810 Crossroads Drive, Suite 4000 Madison, WI 53718 United States | |
Carrer Copèrnic, 2–4, nave 1 Polígon Camí Ral 08850 Gavà Barcelona Spain | www.radiantis.com Tel.: +34 936 38 97 63 |
All wavelengths. Lochhamer Schlag 19 82166 Gräfelfing Germany Quality: ISO 9001:2015 www.toptica.com Social: Facebook, LinkedIn, YouTube E-mail: Tel.: +49 89 85 83 70 Fax: +49 89 85 83 72 00 | TOPTICA contributes to the field of pump–probe measurements with newest fiber technology which is outstanding in performance and versatility. A single laser system can be equipped with various outputs that are intrinsically optically synchronized down to the attosecond level. All of these can be configured individually to satisfy the experimental needs: Pulse durations as short as 15 fs or broad tuning ranges of 490 nm to 700 nm, 850 nm to 1000 nm or 980 nm to 2200 nm are available. Within the third generation of TOPTICA’s ultrafast fiber lasers a novel, versatile toolbox is available to realize even more advanced pump–probe spectroscopy schemes. The FemtoFiber dichro bioMP outputs two different wavelength simultaneously (1050/780 nm at 150 fs), while the system can control the relative time delay of both colors and the GDD as well. |
8330 Consumer Ct. Sarasota, FL 34240 United States | |
Click on a company entry to mark it. Product entries of suppliers having an ad package are displayed with a logo, product description and product image. |
Users: if any displayed information is incorrect (e.g., a listed supplier does not offer such products) or legally problematic, please notify RP Photonics so that the problem can be solved.
Suppliers: you can report modified data using a form, which is provided via the button "Edit profile data" on your company profile page. You can obtain our ad package for getting a much improved visibility and many more leads. (Tell your marketing people about it!)
If you are a supplier and want to be listed, please use the registration form.
An already registered supplier can use a customized form to report the full list of offered photonics products. That form is reachable with a link at the bottom of the supplier's profile page.
Anyone, not only suppliers themselves, can report additional suppliers. If possible, please provide a web address showing that this supplier indeed offers such products.